AC size calculator
How big an air conditioner or heat pump do you need? Size one room from the ENERGY STAR chart, or get a rough tonnage for the whole house.
Cooling capacity needed
8,000 BTU/h
- 300 sq ft: 8,000 BTU/h from the chart
From the ENERGY STAR sizing chart, which assumes an 8 ft ceiling. Pick the nearest size; don’t go much bigger, or the unit cools before it dries the air.
Rough central system size
3.5 tons
42,000 BTU/h; rule-of-thumb range 3–4 tons.
That’s more than one system usually handles (5 tons); large homes often use two.
A starting point only. Ask for a Manual J load calculation before you buy: it often shows a smaller size than rules of thumb, especially in well-sealed homes.
Next: Central AC cost · Heat pump cost · Full HVAC system cost
Room air conditioner sizing chart
From ENERGY STAR, for an 8 ft ceiling, before the adjustments for sun, people and kitchens.
| Room size | Capacity needed |
|---|---|
| 100 up to 150 sq ft | 5,000 BTU/h |
| 150 up to 250 sq ft | 6,000 BTU/h |
| 250 up to 300 sq ft | 7,000 BTU/h |
| 300 up to 350 sq ft | 8,000 BTU/h |
| 350 up to 400 sq ft | 9,000 BTU/h |
| 400 up to 450 sq ft | 10,000 BTU/h |
| 450 up to 550 sq ft | 12,000 BTU/h |
| 550 up to 700 sq ft | 14,000 BTU/h |
| 700 up to 1,000 sq ft | 18,000 BTU/h |
| 1,000 up to 1,200 sq ft | 21,000 BTU/h |
| 1,200 up to 1,400 sq ft | 23,000 BTU/h |
| 1,400 up to 1,500 sq ft | 24,000 BTU/h |
| 1,500 up to 2,000 sq ft | 30,000 BTU/h |
| 2,000 up to 2,500 sq ft | 34,000 BTU/h |
Central AC or heat pump size by house size
Rule of thumb, average insulation, 8 ft ceilings. A starting point only.
| House | Hot | Warm | Mixed | Cold |
|---|---|---|---|---|
| 1,000 sq ft | 2 tons | 2 tons | 2 tons | 1.5 tons |
| 1,500 sq ft | 3 tons | 3 tons | 2.5 tons | 2.5 tons |
| 2,000 sq ft | 4.5 tons | 4 tons | 3.5 tons | 3 tons |
| 2,500 sq ft | 5.5 tons | 5 tons | 4.5 tons | 4 tons |
| 3,000 sq ft | 6.5 tons | 6 tons | 5.5 tons | 4.5 tons |
How this works
For one room we use the ENERGY STAR sizing chart and its four adjustments exactly as published. For a whole house we use the common rule of thumb of about 1 ton per 400 to 600 sq ft. We split that range by climate, move it for insulation (drafty houses need about 18% more; well-sealed newer houses about 23% less, our assumption) and scale it for ceilings over 8 ft, then round to the half-ton sizes systems come in.
Be aware: rules of thumb ignore windows, sun, air leaks and duct losses, and often oversize systems. Contractors who run a Manual J load calculation regularly find homes need less than the rule suggests. In cold climates, a heat pump may be sized for the heating load, which can be larger than the cooling load. How we estimate.
Common questions
What size air conditioner do I need for one room?
Use the ENERGY STAR chart: about 5,000 BTU/h for 100 to 150 sq ft, 8,000 for 300 to 350 sq ft, 12,000 for 450 to 550 sq ft and 18,000 for 700 to 1,000 sq ft. Then take off 10% for a heavily shaded room, add 10% for a very sunny one, add 600 BTU/h for each regular occupant beyond two, and add 4,000 for a kitchen.
What size AC do I need for a 2,000 sq ft house?
Roughly 3 to 4 tons in a mixed climate by the common rule of thumb (about 1 ton per 400 to 600 sq ft, depending on climate). Carrier’s general rule, about 20 BTU per sq ft, puts a typical 2,000 sq ft house at 3 tons. A newer, well-sealed house often needs less; a drafty one in a hot climate may need more. A Manual J load calculation gives the real number.
What is a ton of air conditioning?
One ton is 12,000 BTU per hour of cooling. Central systems for homes come in half-ton steps, usually from 1.5 to 5 tons.
Is a bigger air conditioner better?
No. ENERGY STAR warns that an oversized unit cools the room before it has time to remove the humidity, leaving it cold and clammy. Oversized central systems also switch on and off often, which wastes energy and wears parts. Aim for the right size, not the biggest.
What is a Manual J load calculation?
Manual J is the industry method, published by the Air Conditioning Contractors of America (ACCA), for working out a home’s heating and cooling needs room by room from its insulation, windows, air leaks, orientation and local climate. Ask contractors whether they do one; it often shows a smaller size than rules of thumb.
Sources and method
- ENERGY STAR, Room Air Conditioners: sizing chart (capacities assume an 8 ft ceiling) . Room sizing chart and adjustments for shade, sun, occupants and kitchens
- Air Conditioning Contractors of America (ACCA), Manual J . The industry method for whole-house load calculations
- Carrier, What Size Air Conditioner Do I Need? (October 2026) . About 20 BTU per sq ft as a general rule; 2,000 sq ft typically 3 tons
- Whole-house rule of thumb . About 1 ton per 400–600 sq ft; the split by climate and insulation is our assumption
Built by Engr. Zakir Ullah, an engineer and Google-certified data analyst. Full method: how we estimate. Last reviewed .